CAS 140D-IR Array spectroradiometer for precise infrared radiation measurement

Loading
Loading Loading

CAS 140D-IR – High-performance for wavelengths in the infrared spectral range

Manufacturers of high-class LEDs, luminaires and displays all over the world have for many years been placing their trust in the precise and reliable measuring results of the CAS array spectroradiometer from Instrument Systems.

For measurements of wavelengths above 1100 nm, the CAS 140D-IR model (780 nm – 1700 nm) is available. This infrared model is highly sensitive and therefore designed for particularly low radiant flux levels.

Like all spectrometers from Instrument Systems, the infrared models come with a calibration traceable to the PTB or NIST.

MultiCAS system

By combining the CAS 140D-IR with other CAS 140D models through a trigger box, it is possible to create a MultiCAS system. In this way, complex spectral measurements are simultaneously possible over an extremely wide wavelength range or over multiple samples.

The MultiCAS module of the corresponding SpecWin Pro analytical software evaluates all measurement data by user-friendly means in a common measuring curve.

CAS 140D-IR – Product details:

  • Wavelength range: 780 nm to 1700 nm
  • Cooled detector down to -20° C for minimal dark current
  • Spectrograph with excellent stray light suppression
  • Integral density filter wheel
  • Extensive SpecWin Pro spectral software

Development and quality control of high-quality LEDs

The infrared models of the CAS 140 are among the key measuring instruments in the complex system solutions from Instrument Systems. By virtue of their long service life and reliability, they are employed in the development and quality control of broadband light sources and infrared LEDs.

In combination with other CAS models, the measuring scope of the CAS 140 spectroradiometer in IR results in an extremely wide application spectrum. Solve your measurement tasks with systems from Instrument Systems – in established brands and new challenges, e.g. in transmission, reflection or photovoltaics!

CAS 140 IR series – Technical data

Model versionsCAS 140D-IR  
Spectral range780-1700 nm  
Spectral resolution (100 µm slit)9 nm  
Data point interval2.1 nm  
Stray light for LED0.03 %  
Wavelength measurement accuracy±0.5 nm  
The detailed measurement conditions under which the specified values have been determined can be looked up in the data sheets and brochures or requested from Instrument Systems.